The EI57 is a low-frequency transformer used in industrial measurement equipment. It has two-stage BOOBIN and dual-voltage working mode. OMKG-EI57-004 can provide four sets of working voltages at the same time for the subsequent circuit. Its iron core is fixed with a metal clad frame. With jump wire for input and output terminals, OMKG-EI57-004 has a good reliability and can output voltage with high accuracy.


Product Detail

Product Tags

变压器详情页首图21.8.26

Introduction

The EI57 transformer is mainly used for industrial water level measurement equipment. It supplies power for relay of the equipment and can output four groups of working voltages at the same time under the mode of two input voltage. Since the equipment has high requirements on the accuracy of the working voltage and requires a sufficient safety distance from the primary and secondary, a split BOBBIN is used to process the primary and secondary windings respectively. When the transformer receives a control command, it can accurately drive relay to work.

Low Frequency Transformer (4)

Parameters

ITEMS TEST PIN SPECIFICATION
P(1-3) 100/200V 50/60Hz
AC 100V Output Voltage S1(4-5)
S2(6-7)
S3(8-9)
S4(10-11)
AC21.5V±3%
AC21.5V±3%
AC21.5V±3%
AC8.5V±3%
S1(4-5)
S2(6-7)
S3(8-9)
S4(10-11)
AC20.0V±3%
AC20.0V±3%
AC19.9V±3%
AC8.1V±3%
AC 200V Output Voltage S1(4-5)
S2(6-7)
S3(8-9)
S4(10-11)
AC21.7V±3%
AC21.7V±3%
AC21.7V±3%
AC8.6V±3%
S1(4-5)
S2(6-7)
S3(8-9)
S4(10-11)
AC20.2V±3%
AC20.1V±3%
AC20.1V±3%
AC8.2V±3%
P(1-3) Below 20mA
P(1-3) Below 2.5W
P(1-3) Below 30mA
PRI-SEC
PRI-CORE
AC 2.0KV/1min
SEC-SEC
SEC-CORE
AC 0.5KV/1min
PRI-SEC
PRI SEC-CORE
DC 500V

Dimensions:(Unit: mm)& Diagram

OMKG-EI57-004

Features

1. Two-stage BOBBIN design
2. Reinforced metal frame
3. Jump wire as input and output terminals
4. Reinforced internal leads prevents poor connection caused by accidental stress

Advantages

1. The split BOBBIN structure enhances voltage safety between the primary and secondary and provide bigger room for winding;
2. Heavy weight and thickened frame with ribs ensures a better stability after installation and provides better shock resistance;
3. Lead structure is flexible for installation and wiring so the installation won' t be affected by light changes of base.
4. Multi-channel output voltage with high precision keeps equipment from malfunction